MATEC Web of Conferences

The paper presents the results of the simulation of convectional heat transfer in buildings with radiant gas heating. The study is provided by numerical researches based on existing buildings and numerical studies with the use of modern software ANSYS Multiphysics Fluent, Autodesk Inventor. The data...

Full description

Bibliographic Details
Main Author: Ermolaev, A. N.
Other Authors: Khaustova specialist in the field of mechanical engineering expert of Tomsk Polytechnic University, Turaev
Format: Book Chapter
Language:English
Published: Les Ulis EDP Sciences 2018
Subjects:
Online Access:https://doi.org/10.1051/matecconf/201819401025
http://earchive.tpu.ru/handle/11683/51452
LEADER 02323nla a2200325 4500
001 libtpu00658564
008 181022 2018 0100 m eng
035 0 0 |a (RuTPU)RUTPUnetwork26470 
035 0 0 |a RUTPUnetwork26469 
040 |a RU  |b eng  |c RU  |d Ru-TPU 
100 0 |a Ermolaev, A. N. 
245 1 0 |a MATEC Web of Conferences  |c A. N. Ermolaev, O. V. Khaustova, I. A. Turaev 
260 |a Les Ulis  |b EDP Sciences  |c 2018 
500 |a Title screen 
504 |a [References: 15 tit.] 
520 |a The paper presents the results of the simulation of convectional heat transfer in buildings with radiant gas heating. The study is provided by numerical researches based on existing buildings and numerical studies with the use of modern software ANSYS Multiphysics Fluent, Autodesk Inventor. The data reliability is ensured by the use of fundamental laws in regards to numerical researches and approved mathematic models application; certificated measuring equipment; licensed software products; matching of numerical and experimental researches; matching of the simulation with other works. The simulation of luminous infrared gas emitters of all thermal powers (5, 10, 15, 20, 30, 40 kW) in pre-wall and central placements at heights of 4, 5, 6, 7, 8, 9, 10 m was conducted. Gas-fired infrared heat emitters with heat output of 5, 10, 15, 20, 30, 40 kW were studied. Obtained function of IR-heated zone diameter is close to logarithmic function of thermal output. Effective emitter placement heights and least horizontal pitch for the given room volume were determined. 
653 |a электронный ресурс 
653 |a труды учёных ТПУ 
653 |a моделирование 
653 |a теплопередача 
653 |a здания 
653 |a лучистое отопление 
653 |a газовое отопление 
653 |a конвективный теплообмен 
653 |a численные исследования 
653 |a инфракрасные излучатели 
700 1 |a Khaustova  |c specialist in the field of mechanical engineering  |c expert of Tomsk Polytechnic University  |g Olga Vladimirovna 
700 1 |a Turaev  |g Ilya 
856 4 |u https://doi.org/10.1051/matecconf/201819401025 
856 4 |u http://earchive.tpu.ru/handle/11683/51452