DIAL measurements of the vertical ozone distribution at the Siberian lidar station

The paper presents the results of DIAL measurements of the vertical ozone distribution at the Siberian lidar station. Sensing is performed according to the method of differential absorption and scattering at wavelength pair of 299/341 nm, which are, respectively, the first and second Stokes componen...

Full description

Bibliographic Details
Published in:Proceedings of SPIE Vol. 9645 : Lidar Technologies, Techniques, and Measurements for Atmospheric Remote Sensing XI. P. 96450Q-1-96450Q-5
Corporate Author: Томский государственный университет Факультет инновационных технологий Научные подразделения ФИТ
Other Authors: Romanovskii, O. A., Dolgii, Sergey I., Kharchenko, O. V., Nevzorov, Alexey A., Nevzorov, Alexey V., Burlakov, Vladimir D.
Format: Article
Language:English
Subjects:
Online Access:http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000534512
Перейти в каталог НБ ТГУ
LEADER 02394nab a2200373 c 4500
001 vtls000534512
003 RU-ToGU
005 20230319203620.0
007 cr |
008 190120|2015 xxu s a eng d
024 7 |a 10.1117/12.2194420  |2 doi 
035 |a to000534512 
039 9 |a 201901202136  |c 201901131855  |d staff  |c 201808011009  |d cat202  |c 201605310929  |d cat202  |y 201605300922  |z Александр Эльверович Гилязов 
040 |a RU-ToGU  |b rus  |c RU-ToGU 
245 1 0 |a DIAL measurements of the vertical ozone distribution at the Siberian lidar station  |c O. A. Romanovskii, V. D. Burlakov, S. I. Dolgii [et.al.] 
504 |a Библиогр.: 9 назв. 
520 3 |a The paper presents the results of DIAL measurements of the vertical ozone distribution at the Siberian lidar station. Sensing is performed according to the method of differential absorption and scattering at wavelength pair of 299/341 nm, which are, respectively, the first and second Stokes components of SRS conversion of 4th harmonic of Nd:YAG laser (266 nm) in hydrogen. Lidar with receiving mirror 0.5 m in diameter is used to implement sensing of vertical ozone distribution in altitude range of 6-16 km. The temperature correction of zone absorption coefficients is introduced in the software to reduce the retrieval errors. 
653 |a лидары 
653 |a озон 
653 |a атмосфера 
655 4 |a статьи в журналах  |9 879358 
700 1 |a Romanovskii, O. A.  |9 156354 
700 1 |a Dolgii, Sergey I.  |9 103837 
700 1 |a Kharchenko, O. V.  |9 91224 
700 1 |a Nevzorov, Alexey A.  |9 103838 
700 1 |a Nevzorov, Alexey V.  |9 103839 
700 1 |a Burlakov, Vladimir D.  |9 102910 
710 2 |a Томский государственный университет  |b Факультет инновационных технологий  |b Научные подразделения ФИТ  |9 109408 
773 0 |t Proceedings of SPIE  |d 2015  |g Vol. 9645 : Lidar Technologies, Techniques, and Measurements for Atmospheric Remote Sensing XI. P. 96450Q-1-96450Q-5  |x 0277-786X 
852 4 |a RU-ToGU 
856 7 |u http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000534512 
856 |y Перейти в каталог НБ ТГУ  |u https://koha.lib.tsu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=393782 
908 |a статья 
999 |c 393782  |d 393782