Luminescence of polymethyl methacrylate excited by a runaway electron beam and by a KrCl excilamp

This paper reports an experimental study of luminescence excited in polymethyl methacrylate (PMMA) by a runaway electron beam and by a KrCl excilamp with a wavelength of 222 nm. It is shown that the major contributor to the luminescence of PMMA in both cases is a luminescence band with a maximum int...

Full description

Bibliographic Details
Published in:IEEE transactions on plasma science Vol. 45, № 1. P. 76-84
Other Authors: Tarasenko, Viktor Fedotovich, Burachenko, Alexander G., Beloplotov, Dmitry V., Kozyrev, Andrey V., Baksht, Evgenii Kh
Format: Article
Language:English
Subjects:
Online Access:http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000585652
Перейти в каталог НБ ТГУ
LEADER 02513nab a2200361 c 4500
001 vtls000585652
003 RU-ToGU
005 20240405173333.0
007 cr |
008 171018|2017 xxu s a eng dd
024 7 |a 10.1109/TPS.2016.2637570  |2 doi 
035 |a to000585652 
039 9 |a 201710271637  |b 100  |c 201710270900  |d cat202  |c 201710181536  |d VLOAD  |y 201710181532  |z Александр Эльверович Гилязов 
040 |a RU-ToGU  |b rus  |c RU-ToGU 
245 1 0 |a Luminescence of polymethyl methacrylate excited by a runaway electron beam and by a KrCl excilamp  |c V. F. Tarasenko, E. K. Baksht, A. G. Burachenko [et al.] 
504 |a Библиогр.: 30 назв. 
520 3 |a This paper reports an experimental study of luminescence excited in polymethyl methacrylate (PMMA) by a runaway electron beam and by a KrCl excilamp with a wavelength of 222 nm. It is shown that the major contributor to the luminescence of PMMA in both cases is a luminescence band with a maximum intensity at ~490 nm. Based on experiments with the excilamp, it is supposed that Cherenkov radiation with a wavelength shorter than 300 nm is bound to increase the intensity of this band. The luminescence intensity at ~490 nm varies proportionally with the number of beam electrons, allowing the use of this radiation to determine the number of high-energy electrons in electron beams. In PMMA with high absorption at 300-400 nm, one more luminescence band with a maximum intensity at ~400 nm is observed. It is confirmed that in gas diodes at a pressure of 760 torr, the intensity of Cherenkov radiation against the background of luminescence is low and undetectable. 
653 |a эксилампы 
653 |a люминесценция 
653 |a полиметилметакрилат 
653 |a убегающие электроны 
655 4 |a статьи в журналах  |9 879358 
700 1 |a Tarasenko, Viktor Fedotovich  |9 76225 
700 1 |a Burachenko, Alexander G.  |9 103807 
700 1 |a Beloplotov, Dmitry V.  |9 109407 
700 1 |a Kozyrev, Andrey V.  |9 90272 
700 1 |a Baksht, Evgenii Kh.  |9 101604 
773 0 |t IEEE transactions on plasma science  |d 2017  |g Vol. 45, № 1. P. 76-84  |x 0093-3813 
852 4 |a RU-ToGU 
856 7 |u http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000585652 
856 |y Перейти в каталог НБ ТГУ  |u https://koha.lib.tsu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=427994 
908 |a статья 
999 |c 427994  |d 427994