Luminescence of polymethyl methacrylate excited by a runaway electron beam and by a KrCl excilamp
This paper reports an experimental study of luminescence excited in polymethyl methacrylate (PMMA) by a runaway electron beam and by a KrCl excilamp with a wavelength of 222 nm. It is shown that the major contributor to the luminescence of PMMA in both cases is a luminescence band with a maximum int...
Published in: | IEEE transactions on plasma science Vol. 45, № 1. P. 76-84 |
---|---|
Other Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000585652 Перейти в каталог НБ ТГУ |
LEADER | 02513nab a2200361 c 4500 | ||
---|---|---|---|
001 | vtls000585652 | ||
003 | RU-ToGU | ||
005 | 20240405173333.0 | ||
007 | cr | | ||
008 | 171018|2017 xxu s a eng dd | ||
024 | 7 | |a 10.1109/TPS.2016.2637570 |2 doi | |
035 | |a to000585652 | ||
039 | 9 | |a 201710271637 |b 100 |c 201710270900 |d cat202 |c 201710181536 |d VLOAD |y 201710181532 |z Александр Эльверович Гилязов | |
040 | |a RU-ToGU |b rus |c RU-ToGU | ||
245 | 1 | 0 | |a Luminescence of polymethyl methacrylate excited by a runaway electron beam and by a KrCl excilamp |c V. F. Tarasenko, E. K. Baksht, A. G. Burachenko [et al.] |
504 | |a Библиогр.: 30 назв. | ||
520 | 3 | |a This paper reports an experimental study of luminescence excited in polymethyl methacrylate (PMMA) by a runaway electron beam and by a KrCl excilamp with a wavelength of 222 nm. It is shown that the major contributor to the luminescence of PMMA in both cases is a luminescence band with a maximum intensity at ~490 nm. Based on experiments with the excilamp, it is supposed that Cherenkov radiation with a wavelength shorter than 300 nm is bound to increase the intensity of this band. The luminescence intensity at ~490 nm varies proportionally with the number of beam electrons, allowing the use of this radiation to determine the number of high-energy electrons in electron beams. In PMMA with high absorption at 300-400 nm, one more luminescence band with a maximum intensity at ~400 nm is observed. It is confirmed that in gas diodes at a pressure of 760 torr, the intensity of Cherenkov radiation against the background of luminescence is low and undetectable. | |
653 | |a эксилампы | ||
653 | |a люминесценция | ||
653 | |a полиметилметакрилат | ||
653 | |a убегающие электроны | ||
655 | 4 | |a статьи в журналах |9 879358 | |
700 | 1 | |a Tarasenko, Viktor Fedotovich |9 76225 | |
700 | 1 | |a Burachenko, Alexander G. |9 103807 | |
700 | 1 | |a Beloplotov, Dmitry V. |9 109407 | |
700 | 1 | |a Kozyrev, Andrey V. |9 90272 | |
700 | 1 | |a Baksht, Evgenii Kh. |9 101604 | |
773 | 0 | |t IEEE transactions on plasma science |d 2017 |g Vol. 45, № 1. P. 76-84 |x 0093-3813 | |
852 | 4 | |a RU-ToGU | |
856 | 7 | |u http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000585652 | |
856 | |y Перейти в каталог НБ ТГУ |u https://koha.lib.tsu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=427994 | ||
908 | |a статья | ||
999 | |c 427994 |d 427994 |