Glucose diffusion in colorectal mucosa - a comparative study between normal and cancer tissues

Colorectal carcinoma is a major health concern worldwide and its high incidence and mortality require accurate screening methods. Following endoscopic examination, polyps must be removed for histopathological characterization. Aiming to contribute to the improvement of current endoscopy methods of c...

Полное описание

Библиографическая информация
Опубликовано в: :Journal of biomedical optics Vol. 22, № 9. P. 091506-1-091506-12
Другие авторы: Carvalho, Sónia D., Nogueira, Elisabete, Henrique, Rui M., Oliveira, Luís Manuel, Tuchin, Valery V., Gueiral, Nuno
Формат: Статья в журнале
Язык:English
Предметы:
Online-ссылка:http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000618341
Перейти в каталог НБ ТГУ
LEADER 03004nab a2200385 c 4500
001 vtls000618341
003 RU-ToGU
005 20231123174304.0
007 cr |
008 171221|2017 xxu s a eng d
024 7 |a 10.1117/1.JBO.22.9.091506  |2 doi 
035 |a to000618341 
039 9 |a 201712250839  |b 100  |c 201712211551  |d VLOAD  |y 201712211537  |z Александр Эльверович Гилязов 
040 |a RU-ToGU  |b rus  |c RU-ToGU 
245 1 0 |a Glucose diffusion in colorectal mucosa - a comparative study between normal and cancer tissues  |c S. Carvalho, N. Gueiral, E. Nogueira [et.al.] 
504 |a Библиогр.: 52 назв. 
520 3 |a Colorectal carcinoma is a major health concern worldwide and its high incidence and mortality require accurate screening methods. Following endoscopic examination, polyps must be removed for histopathological characterization. Aiming to contribute to the improvement of current endoscopy methods of colorectal carcinoma screening or even for future development of laser treatment procedures, we studied the diffusion properties of glucose and water in colorectal healthy and pathological mucosa. These parameters characterize the tissue dehydration and the refractive index matching mechanisms of optical clearing (OC). We used ex vivo tissues to measure the collimated transmittance spectra and thickness during treatments with OC solutions containing glucose in different concentrations. These time dependencies allowed for estimating the diffusion time and diffusion coefficient values of glucose and water in both types of tissues. The measured diffusion times for glucose in healthy and pathological mucosa samples were 299.2 ± 4.7 ?? s and 320.6 ± 10.6 ?? s for 40% and 35% glucose concentrations, respectively. Such a difference indicates a slower glucose diffusion in cancer tissues, which originate from their ability to trap far more glucose than healthy tissues. We have also found a higher free water content in cancerous tissue that is estimated as 64.4% instead of 59.4% for healthy mucosa. 
653 |a колоректальный рак 
653 |a диффузия глюкозы 
653 |a обезвоживание тканей 
653 |a коэффициент диффузии 
653 |a вода 
655 4 |a статьи в журналах  |9 879358 
700 1 |a Carvalho, Sónia D.  |9 898991 
700 1 |a Nogueira, Elisabete  |9 478873 
700 1 |a Henrique, Rui M.  |9 898992 
700 1 |a Oliveira, Luís Manuel  |9 855298 
700 1 |a Tuchin, Valery V.  |9 78712 
700 1 |a Gueiral, Nuno  |9 478874 
773 0 |t Journal of biomedical optics  |d 2017  |g Vol. 22, № 9. P. 091506-1-091506-12  |x 1083-3668 
852 4 |a RU-ToGU 
856 7 |u http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000618341 
856 |y Перейти в каталог НБ ТГУ  |u https://koha.lib.tsu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=429233 
908 |a статья 
999 |c 429233  |d 429233