We have performed a detailed study of the dependence of afterpulse probability in InGaAs/InP sine-gated SPAD on the dead time and the existing approach for its implementation. We demonstrated an electrical scheme combining sinusoidal gating and active reset. We have shown when such solutions are ben...

Full description

Bibliographic Details
Published in:IEEE journal of quantum electronics Vol. 58, № 3. P. 4500111 (1-11)
Other Authors: Losev, Anton V., Zavodilenko, Vladimir V., Koziy, Andrey A., Filyaev, Alexandr A., Khomyakova, Kristina I., Kurochkin, Yury V., Gorbatsevich, Alexander A.
Format: Article
Language:English
Subjects:
Online Access:http://vital.lib.tsu.ru/vital/access/manager/Repository/koha:001001185
LEADER 02154nab a2200361 c 4500
001 koha001001185
005 20230511134804.0
007 cr |
008 230502|2022 xxu s a eng d
024 7 |a 10.1109/JQE.2022.3171671  |2 doi 
035 |a koha001001185 
040 |a RU-ToGU  |b rus  |c RU-ToGU 
245 1 0 |a Dead time duration and active reset influence on the afterpulse probability of InGaAs/InP single-photon avalanche diodes  |c A. V. Losev, V. V. Zavodilenko, A. A. Koziy [et al.] 
336 |a Текст 
337 |a электронный 
504 |a Библиогр.: 47 назв. 
520 3 |a We have performed a detailed study of the dependence of afterpulse probability in InGaAs/InP sine-gated SPAD on the dead time and the existing approach for its implementation. We demonstrated an electrical scheme combining sinusoidal gating and active reset. We have shown when such solutions are beneficial from the key distribution point of view, and enough to use a simple scheme with a snatching comparator. We have also proposed a precise method for measuring the afterpulse and presented a model describing the non-markovian dynamic of this effect. We have demonstrated that our afterpulsing measurement approach makes these measurements less dependent on the parameters of the flow of the diode and the laser pulses' power changes, in contrast to the other methods considered in this paper. 
653 |a однофотонные детекторы 
653 |a мертвое время 
653 |a однофотонные лавинные диоды 
655 4 |a статьи в журналах 
700 1 |a Losev, Anton V. 
700 1 |a Zavodilenko, Vladimir V. 
700 1 |a Koziy, Andrey A. 
700 1 |a Filyaev, Alexandr A. 
700 1 |a Khomyakova, Kristina I. 
700 1 |a Kurochkin, Yury V. 
700 1 |a Gorbatsevich, Alexander A. 
773 0 |t IEEE journal of quantum electronics  |d 2022  |g Vol. 58, № 3. P. 4500111 (1-11)  |x 0018-9197  |w 0032-90360 
852 4 |a RU-ToGU 
856 4 |u http://vital.lib.tsu.ru/vital/access/manager/Repository/koha:001001185 
908 |a статья 
999 |c 1001185  |d 1001185