Ignition resistance of wood building structures exposed to a firebrand shower
The interaction of a firebrand shower with some types of combustible building materials and wood structures was studied experimentally. The heat flux generated by firebrands was determined, and the temperature fields of the most heat-stressed sections of the structures were analyzed. The heating rat...
| Published in: | Combustion, explosion, and shock waves Vol. 59, № 2. P. 206-214 |
|---|---|
| Other Authors: | Kasymov, Denis P., Agafontsev, Mikhail V., Perminov, Vladislav V., Loboda, Egor L., Reino, V. V., Orlov, Konstantin E. |