Ignition resistance of wood building structures exposed to a firebrand shower

The interaction of a firebrand shower with some types of combustible building materials and wood structures was studied experimentally. The heat flux generated by firebrands was determined, and the temperature fields of the most heat-stressed sections of the structures were analyzed. The heating rat...

Полное описание

Библиографическая информация
Опубликовано в: :Combustion, explosion, and shock waves Vol. 59, № 2. P. 206-214
Другие авторы: Kasymov, Denis P., Agafontsev, Mikhail V., Perminov, Vladislav V., Loboda, Egor L., Reino, V. V., Orlov, Konstantin E.
Формат: Статья в журнале
Язык:English
Предметы:
Online-ссылка:http://vital.lib.tsu.ru/vital/access/manager/Repository/koha:001016654