Colorimetric determination of bromate in drinking water using methyl red immobilized into polymethacrylate matrix

This article presents solid-phase spectrophotometric method of bromate determination using methyl red immobilised into transparent polymethacrylate matrix. The method is based on oxygenation of the indicator immobilised into the matrix by a bromate. We discovered the optimal conditions for bromate d...

Полное описание

Библиографическая информация
Опубликовано в: :International journal of environmental analytical chemistry Vol. 103, № 5. P. 1011-1019
Другие авторы: Saranchina, Nadezhda V., Trifonova, N. S., Urazov, E. V., Gavrilenko, Nataliya A., Gavrilenko, Mikhail A.
Формат: Статья в журнале
Язык:English
Предметы:
Online-ссылка:https://vital.lib.tsu.ru/vital/access/manager/Repository/koha:001156459
Перейти в каталог НБ ТГУ
LEADER 02625nab a2200373 c 4500
001 koha001156459
005 20250430165356.0
007 cr |
008 250424|2023 ne s a eng d
024 7 |a 10.1080/03067319.2020.1866565  |2 doi 
035 |a koha001156459 
040 |a RU-ToGU  |b rus  |c RU-ToGU 
245 1 0 |a Colorimetric determination of bromate in drinking water using methyl red immobilized into polymethacrylate matrix  |c N. V. Saranchina, N. S. Trifonova, E. V. Urazov [et al.] 
336 |a Текст 
337 |a электронный 
504 |a Библиогр.: 39 назв. 
520 3 |a This article presents solid-phase spectrophotometric method of bromate determination using methyl red immobilised into transparent polymethacrylate matrix. The method is based on oxygenation of the indicator immobilised into the matrix by a bromate. We discovered the optimal conditions for bromate determination, studied the effect of interference of the foreign ions, and evaluated the analytical performance of the suggested method. The method we developed makes it possible to quantify the content of a bromate in the concentration range of 0.1-1.0 mg·L−1 with the limit of detection 0.01 mg·L−1. The mean relative standard deviation of the results was ≤1.2%, which confirmed reproducibility of this assay technique. We demonstrated usability of the suggested method for detection of bromates in drinking water using solid-phase spectrophotometry without any preliminary sample preparation. Polymethacrylate matrix with methyl red immobilised into it can be used as a ready-made analytical form for the rapid visual bromate determination test. 
653 |a полиметакрилатная матрица 
653 |a твердофазная спектрофотометрия 
653 |a визуальное определение 
653 |a метиловый красный 
655 4 |a статьи в журналах 
700 1 |a Saranchina, Nadezhda V.  |9 98632 
700 1 |a Trifonova, N. S.  |9 988875 
700 1 |a Urazov, E. V.  |9 500982 
700 1 |a Gavrilenko, Nataliya A.  |9 98631 
700 1 |a Gavrilenko, Mikhail A.  |9 98642 
773 0 |t International journal of environmental analytical chemistry  |d 2023  |g Vol. 103, № 5. P. 1011-1019  |x 0306-7319 
852 4 |a RU-ToGU 
856 4 |u https://vital.lib.tsu.ru/vital/access/manager/Repository/koha:001156459 
856 |y Перейти в каталог НБ ТГУ  |u https://koha.lib.tsu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=1156459 
908 |a статья 
999 |c 1156459  |d 1156459 
039 |b 100