Infrared thermographic testing of hyperconductive flat heat pipes

Active infrared thermography has been applied for the evaluation of the internal structure and operation quality of hyperconductive flat mini heat pipes used in satellite electronics. The distribution of effective transverse thermal diffusivity in heat pipes has been obtained by means of the Parker...

Полное описание

Библиографическая информация
Опубликовано в: :Optical engineering Vol. 57, № 3. P. 035105-1-035105-6
Другие авторы: Chulkov, Arsenii O., Vavilov, Vladimir P., Suntsov, Sergei B., Simonova, Olga S.
Формат: Статья в журнале
Язык:English
Предметы:
Online-ссылка:http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000789743
Перейти в каталог НБ ТГУ